Edmonton Egress Window Requirements: Basement Fire Escapes
Published for YEG Residents • Municipal Reference: Alberta Building Code
A finished basement adds massive value to an Edmonton home, but converting that space into a legal bedroom comes with strict life-or-death regulations. Governed by the Alberta Building Code, every bedroom must be equipped with at least one "egress window"—a window large enough to serve as a secondary fire escape.
The dimensional requirements are non-negotiable. An egress window must provide a minimum unobstructed openable area of 0.35 square meters (3.8 square feet). To ensure a fully geared firefighter with an oxygen tank can enter, no single dimension—whether height or width—can be less than 380 millimeters (15 inches) when the window is fully open.
For basement bedrooms where the window is situated below ground level, a proper window well must be excavated. The well must project outward from the window by at least 760 millimeters (30 inches) to give escaping occupants enough room to maneuver. If your window well is deep, or if the window sits higher than 1.5 meters from the floor, you may also be required to install permanent escape steps or a mounted ladder to pass your municipal inspection.
| Egress Requirement | Alberta Building Code Standard | Pass/Fail Details |
|---|---|---|
| Minimum Open Area | 0.35 sq. meters (3.8 sq. ft.) | Measured when window is fully opened |
| Minimum Dimension | 380 mm (15 inches) | Applies to both width and height |
| Window Well Clearance | 760 mm (30 inches) outward | Ensures room to climb out of the well |
| Security Bars/Grilles | Must be openable from inside | Cannot require keys or special tools |
Need to Apply for a Basement Renovation Permit?
Ensure your window dimensions and concrete cut plans are submitted accurately for approval.